Field report
Air Quality Monitoring Report Across Selected Indoor and Outdoor Locations in Wandsworth Council, London
- Published
- 2026
- Authors
- Roehampton Sustainable Futures Hub, in partnership with A Greener London
Abstract
This report presents the findings of an indoor and outdoor air quality monitoring study carried out across seven selected locations in Wandsworth Council, London, as part of the Air & Living Infrastructure Initiative delivered in partnership with A Greener London. The study assessed pollutant levels, ventilation performance, and comfort conditions across educational, residential, commercial, sporting, and high-traffic environments using Airthings indoor air quality monitoring devices. Findings are benchmarked against UK Health and Safety Executive ventilation guidance and World Health Organization air quality guideline values, and are intended to support practical, site-specific improvements to occupant health, comfort, and environmental resilience across the borough.
Location: Wandsworth Council, London | Monitoring Period: March – June 2026 | Partner Organisation: A Greener London | Initiative: Air & Living Infrastructure Initiative (ALII), Roehampton Sustainable Futures Hub
Methods
- Continuous indoor air quality monitoring at seven locations using Airthings devices (Space Pro, Space Plus, Space CO2 configurations), tracking CO2, temperature, relative humidity, VOCs, PM2.5, PM1, relative light, and noise.
- Monitoring periods ranged from two to several weeks per site between March and June 2026, with results interpreted against opening-hour averages to reflect real occupancy conditions.
- A virus risk screening indicator was applied where supported, based on ventilation rate, occupancy, and humidity rather than direct viral measurement.
- Findings were benchmarked using HSE ventilation guidance, WHO air quality guideline values for particulate matter, and standard indoor comfort ranges for temperature and humidity.
Key Findings
- Venture X Business Center and Southland Reef showed the strongest overall air quality performance, with consistently good CO2, VOC, particulate matter, temperature, and humidity readings.
- River Homes and Roehampton Sports Center recorded fair average CO2 and PM2.5 levels, indicating that naturally ventilated spaces experienced greater ventilation pressure during occupied periods.
- Hurlingham School performed well overall but recorded occasional short-term CO2 peaks during periods of higher classroom occupancy.
- Shaw Building, a university hostel, showed good pollutant control but poor thermal comfort, with average temperatures rated below recommended comfort thresholds.
- Putney High Street showed good CO2, temperature, and humidity readings, but the available dataset lacked PM2.5, PM10, NO2, and ozone data needed for a full assessment of traffic-related roadside exposure.
- Recommended actions include CO2-guided ventilation, HEPA filtration where particulate levels remain elevated, low-VOC cleaning products, improved thermal comfort management, expanded outdoor traffic pollutant monitoring, and the use of living walls and green infrastructure as complementary wellbeing interventions.
Cite this report
APA 7th Edition
Roehampton Sustainable Futures Hub, & A Greener London. (2026). Air quality monitoring report across selected indoor and outdoor locations in Wandsworth Council, London. Field report, Air & Living Infrastructure Initiative, Roehampton Sustainable Futures Hub, University of Roehampton, London, United Kingdom, in partnership with A Greener London.